SSG04
Cardiac (Aortic and Mitral Valves)
Scientific Formal (Paper) Presentations
—
Cardiac Radiology, Computed Tomography,
Presented on November 27, 2012
SSG04-01 |
Transcatheter Aortic Valve Replacement: Performance of an Aortic Valvular Complex Model for Semi-Automated Quantification of Aortic Annulus Dimensions at Cardiac CT
U. Joseph Schoepf MD | Philipp Blanke MD | Mathias Langer MD, PhD | Thomas Flohr PhD | Dominik Bernhardt | Razvan Ionasec PhD | Michael Scheuering PhD
|
SSG04-02 |
Conformational Pulsatile Changes of the Aortic Annulus: Impact on Prosthesis Sizing by Computed Tomography for Transcatheter Aortic Valve Replacement
U. Joseph Schoepf MD | Philipp Blanke MD | Jonathan Leipsic MD | Ullrich Ebersberger MD | Gregor Pache MD | Mathias Langer MD, PhD | Maximilian Russe | Pal Suranyi MD, PhD
|
SSG04-03 |
Computed Tomography-based Prediction of Angiographic Development Angles Reduces Contrast Medium Volume and Procedure Time for Transcatheter Aortic Valve Replacement (TAVR)
Dominik Fleischmann MD | Theodore Blake MD | Catherine Dao MD | D. Craig Miller | William Fearon MD | Michael Fischbein
|
SSG04-04 |
MSC-guided Sizing of the Edwards Sapien XT TAVI Device and Post implantation Geometry in Relation to Pre-procedural Aortic Anulus Anatomy: An Evaluation by MSCT
Ulrich Platz | Alexander Leber MD, PhD | Hans Ullrich Ebersberger | Markus Kasel
|
SSG04-05 |
A Modern Computed Tomography Sizing Guideline for Balloon Expandable Transcatheter Aortic Valve Replacement
Jonathan Leipsic MD | Cameron Hague MD | David Wood MD, FRCPC | John Webb MD, FRCPC | Alexander Willson | Ronald Binder
|
SSG04-06 |
Comparison of High Pitch Non-ECG-triggered MDCT of the Aortic Root with Retrospective ECG-gated Helical MDCT, Measurements of Aortic Root and Aortic Valve in Pre-TAVI Assessment
Joachim Wildberger MD, PhD | Tomas Jurencak | Marco Das MD | Bastiaan Kietselaer | Leen van Garsse
|
SSG04-07 |
Cardiac Computed Tomography in Localization of Mitral Valve Prolapse: Scallop-by-Scallop Comparison with Transesophageal Echocardiography and Intraoperative Findings
Dong Hyun Yang MD | Joon-Won Kang MD | Tae-Hwan Lim MD, PhD | Jae-Kwan Song MD, PhD | Jae Won Lee MD
|
SSG04-08 |
From Unicuspid to Quadricuspid: Impact of Valve Morphology on Aortic 3D Blood Flow
Amir Davarpanahfakhr MD | James Carr MD | Riti Mahadevia | Pegah Entezari MD | Susanne Schnell | Daniel Rinewalt | Bernd Jung | Chris Malaisrie | Patrick McCarthy MD | Jeremy Collins MD | Alex Barker | Michael Markl PhD
|
SSG04-09 |
CT-based Instantaneous Calculation of Viewing Angles for Device Deployment in Patients Undergoing Transcatheter Aortic Valve Replacement (TAVR)
Dominik Fleischmann MD | Franz Boas MD, PhD | Theodore Blake MD | Catherine Dao MD | D. Craig Miller | William Fearon MD
|
Flamm, S,
White, R,
Cardiac (Aortic and Mitral Valves). Radiological Society of North America 2012 Scientific Assembly and Annual Meeting, November 25 - November 30, 2012 ,Chicago IL.
http://archive.rsna.org/2012/12038756.html