AwardsStudent Travel Stipend Award
ParticipantsJooae Choe, MD, Seoul, Korea, Republic Of (Presenter) Nothing to Disclose
Sang Min Lee, MD, Seoul, Korea, Republic Of (Abstract Co-Author) Nothing to Disclose
Kyunghee Lee, MD, PhD, Seongnam, Korea, Republic Of (Abstract Co-Author) Nothing to Disclose
Kyu-Hwan Jung, PhD, Seoul, Korea, Republic Of (Abstract Co-Author) Stockholder, VUNO Inc
Jaeyoun Yi, Seoul, Korea, Republic Of (Abstract Co-Author) Officer, Coreline Soft, Co Ltd
Sang Min Lee, MD, Seoul, Korea, Republic Of (Abstract Co-Author) Nothing to Disclose
Joon Beom Seo, MD, PhD, Seoul, Korea, Republic Of (Abstract Co-Author) Nothing to Disclose
sangmin.lee.md@gmail.com
PURPOSETo evaluate the added value of a deep-learning based computer-aided detection (CAD) system for multiclass multiple lesions on radiographs when radiologists read chest radiographs.
METHOD AND MATERIALSWe developed new CAD system using deep learning for detecting multiple lesions with 4 different patterns (nodule/mass, interstitial opacity, pleural effusion, and pneumothorax) on chest radiograph. To train the deep learning network, 17917 images were collected in two tertiary hospitals. Numbers of normal and abnormal patients are 11000 and 6917, respectively. We labeled disease type and delineate region of interests (ROI) drawn as ground truths by two thoracic radiologists with consensus. To validate the effect of the developed CAD on observer's performance, 9 observers including 7 board-certified radiologists and two radiology residents reviewed 200 chest radiographs twice with two weeks interval. 200 chest radiographs consists of 100 normal and 100 abnormal (nodule/mass: 60, interstitial opacity: 10, pleural effusion: 10, pneumothorax: 10) chest radiographs. The diagnostic performance of the developed CAD, observers with and without CAD were evaluated and compared using jackknife free-response receiver operating characteristic (JAFROC) figure of merits (FOMs) on a per-lesion basis. The reading time for review was recorded.
RESULTSThe developed CAD showed FOMs of 0.931 for nodule/mass, 0.900 for interstitial opacity, 1 for pleural effusion, and 1 for pneumothorax. The mean FOMs of 9 observers without CAD were 0.916 for nodule/mass, 0.922 for interstitial opacity, 0.944 for pleural effusion, and 0.978 for pneumothorax. After applying the CAD, the mean FOMs of 9 observers were 0.942 for nodule/mass, 0.900 for interstitial opacity, 0.967 for pleural effusion, and 1 for pneumothorax. Except for interstitial opacity, the accuracy of three patterns with CAD increased. The mean reading time was 91.5 minutes ± 53.2 without CAD and 79.1 minutes ± 28.2 with CAD.
CONCLUSIONThe deep-learning based CAD may help improve observer performance for reading chest radiograph as well as reducing reading time.