RSNA 2012 

Abstract Archives of the RSNA, 2012


SSM13-03

Pseudostenosis of Vertebral Artery Ostium on 3D Contrast-enhanced MRA in Comparison with Motion of Aortic Arch on Dynamic 4D MRA

Scientific Formal (Paper) Presentations

Presented on November 28, 2012
Presented as part of SSM13: Neuroradiology (Vascular Imaging)

Participants

Gene Hyuk Kwon, Presenter: Nothing to Disclose
Seonmun Kim, Abstract Co-Author: Nothing to Disclose
Hyun Seok Choi MD, Abstract Co-Author: Nothing to Disclose
So Lyung Jung, Abstract Co-Author: Nothing to Disclose
Kookjin Ahn MD, PhD, Abstract Co-Author: Nothing to Disclose
Bum-Soo Kim MD, PhD, Abstract Co-Author: Nothing to Disclose

PURPOSE

Vertebral artery ostium is a frequent site of pseudostenosis on 3D contrast-enhanced MRA (CE-MRA). Therefore, there is a high false positive rate in diagnosing vertebral artery ostial stenosis using CE-MRA. Motion of aortic arch due to cardiac and respiration is considered as a cause of pseudostenosis at this site. The purpose of this study is to confirm the hypothesis that pseudostenosis of vertebral artery ostium is associated with motion of aortic arch.

METHOD AND MATERIALS

47 patients were enrolled in this study. They underwent CTA, CE-MRA, and dynamic 4D MRA with an interval of 6.87±9.89 days (mean ± SD). All CTA was performed with 64-channel MDCT. CE-MRA was performed after injection of Gadovist (0.1cc/kg). Dynamic 4D MRA was performed after injection of 0.1ml of Gadovist. CTA was used as a reference standard of vertebral artery ostial stenosis. We measured percent stenosis of vertebral artery ostium using NASCET criteria. VA ostium was graded as <50% stenosis, 50-99% stenosis, and occlusion. Motion of aortic arch was visualized with temporal resolution of 1-second on 4D MRA. Distance between the highest position and lowest position of aortic arch during the dynamic 4D MRA was measured as motion of aortic arch. Age, route of intravenous contrast media, motion of aortic arch, and normal distal diameter of VA were statistically analyzed.

RESULTS

Total 17 patients showed unilateral or bilateral pseudostenosis of vertebral artery ostia (36.2%). There were 23 pseudostenoses of vertebral artery ostia out of 94 (24.5%). Patients with pseudostenosis showed higher motion of aortic arch (3.61±1.87 vs 2.05±1.97 cm) and older age (71.3±8.9 vs. 64.2±13.4 year-old). Route of intravenous contrast media and normal distal diameter of VA were not associated with pseudostnosis.

CONCLUSION

Pseudostenosis of VA ostia is frequently seen on CE-MRA. Pseudostenosis of VA ostia should be considered when higher motion of aortic arch is visualized on dynamic 4D MRA.

CLINICAL RELEVANCE/APPLICATION

We can avoid mis-diagnosis of vertebral artery ostial stenosis when patients show higher motion of aortic arch on dynamic 4D MRA.

Cite This Abstract

Kwon, G, Kim, S, Choi, H, Jung, S, Ahn, K, Kim, B, Pseudostenosis of Vertebral Artery Ostium on 3D Contrast-enhanced MRA in Comparison with Motion of Aortic Arch on Dynamic 4D MRA.  Radiological Society of North America 2012 Scientific Assembly and Annual Meeting, November 25 - November 30, 2012 ,Chicago IL. http://archive.rsna.org/2012/12029682.html