RSNA 2006 

Abstract Archives of the RSNA, 2006


SSA18-09

Monte Carlo Transport Calculations for Fields with Dynamic Beam Modifiers

Scientific Papers

Presented on November 26, 2006
Presented as part of SSA18: Physics (Radiation Therapy)

Participants

Sami Siljamäki PhD, Presenter: Employee, Varian Medical Systems, Inc
Laura Tillikainen, Abstract Co-Author: Employee, Varian Medical Systems, Inc
Katja Pesola FRCPC, Abstract Co-Author: Employee, Varian Medical Systems, Inc

PURPOSE

Monte Carlo methods are becoming widely used for dose calculation in radiotherapy treatment planning. With constantly increasing computer power, new kind of Monte Carlo applications reach performance level which is suitable for clinical uses. Monte Carlo methods have been used to calculate dose deposition in a patient, e.g., from pre-simulated phase-space input files. More recently, full transport calculations for the accelerator head are, however, becoming possible as well. They can be used to very accurately model the beam modifiers in a linear accelerator. These include jaws, hard and dynamic wedges, multi-leaf collimators, blocks, etc. In particular, dose calculation for very complex dynamic fields benefit greatly from the use of Monte Carlo methods.

METHOD AND MATERIALS

In this work, VMC++-based (Voxel Monte Carlo, National Research Council, Canada) algorithm is used to simulate the linear accelerator head for fields with dynamic beam modifiers. The transport calculations are based on VMC++ algorithm, and using advanced variance reduction techniques the computation time is greatly reduced, compared to standard Monte Carlo codes, without reducing the calculation accuracy. We do not concentrate on the initial beam generation, i.e., target, primary collimator or flattening filter. These components are modeled by a previously developed source model for a superposition/convolution dose calculation algorithm, and particles are generated from this model before transport through the other beam modifiers. This approach has the advantage that the model can be easily adapted to nearly any clinical beam data set; with a Monte-Carlo-only simulation of the whole accelerator head, the configuration of even a single machine would be much more difficult. The source model has also been shown to be realistic and representative of typical beams. The patient dose calculation is done using the same VMC++ code that is used for the transport calculation. The patient dose calculations are done in order to validate our dynamic transport code, and are not a subject of this work.

RESULTS

We have developed dynamic Monte Carlo components, and efficient description of the geometry of various beam modifier objects. Results are presented for dynamic wedges, MLC’s, and arc fields. The results are compared to measurements, and the agreement is excellent for all cases. The calculation time varies from a few minutes to a few hours, depending on the required accuracy and target volume.

CONCLUSION

Monte Carlo is shown to be a very competitive alternative for traditional methods in modeling accessories, especially for dynamic treatments. The results of the corresponding dose calculation match very well with measured beam data. In addition, the obtained execution times are suitable for routine clinical use.

Cite This Abstract

Siljamäki, S, Tillikainen, L, Pesola, K, Monte Carlo Transport Calculations for Fields with Dynamic Beam Modifiers.  Radiological Society of North America 2006 Scientific Assembly and Annual Meeting, November 26 - December 1, 2006 ,Chicago IL. http://archive.rsna.org/2006/8001518.html