Abstract Archives of the RSNA, 2006
SSA18-02
Intralesional Chemotherapy Depot Improves Outcome of Radiofrequency Ablation in Experimental Carcinoma
Scientific Papers
Presented on November 26, 2006
Presented as part of SSA18: Physics (Radiation Therapy)
Tianyi Ma Krupka BS, Presenter: Nothing to Disclose
Brent Derek Weinberg BS, Abstract Co-Author: Nothing to Disclose
John Robert Haaga MD, Abstract Co-Author: Nothing to Disclose
Agata A. Exner PhD, Abstract Co-Author: Nothing to Disclose
To investigate the efficacy of radiofrequency ablation (RFA) combined with intralesional chemotherapy administered via an in situ-forming polymer depot in treatment of experimental carcinoma in rats.
18 BD-IX rats were inoculated with bilateral subcutaneous tumors via injection of DHD/K12TRb rat colorectal carcinoma cells in suspension. 4 weeks after inoculation tumors were treated with RFA (RadionicsTM, 21G electrode, 2 min, 80ºC). Next, one tumor per animal received a carboplatin-loaded polymer depot (100µl, 8.4mg/kg) injected directly into the ablation site. Two depot formulations, with (treatment I, n=9) and without (treatment II, n=8) a chemosensitizer were tested. Tumor diameter was measured with calipers weekly for two weeks. Treatment efficacy was assessed by change in tumor diameter, percent of coagulation necrosis and completeness of treatment. Complete treatment grading was assigned to tumors that showed 100% coagulation necrosis based on histology.
1/18 animals did not show visible tumor at treatment day and was excluded from the study. Tumors treated with ablation and drug treatment I (carboplatin + sensitizer, n=9) showed a decrease of 6.7±14.4% at week 1, and a decrease of 49.4±25.5% at the endpoint relative to ablation control. Tumors treated with ablation and drug treatment II (carboplatin only, n=8) showed a 27.2±16.1% increase at week 1 and 7.1±12.6% decrease two weeks after the treatment relative to ablation control. Treatment I produced increased coagulation necrosis (81.9±9.7%), and resulted in double the number of complete treatments (6/9 or 66.7%) compared to 3/9 or 33.3% in the ablation control. Treatment II also resulted in increased necrosis (91.9±3.2%), but showed no difference in the number of complete treatments (50.0% in both groups).
Intralesional administration of a carboplatin-loaded polymer depot following RFA doubles the number of complete treatments in a rat adenocarcinoma model.
This injectable depot has the potential to improve the outcome of RFA therapy by providing local adjuvant chemotherapy to prevent local progression of tumor unaffected by the RFA.
Krupka, T,
Weinberg, B,
Haaga, J,
Exner, A,
Intralesional Chemotherapy Depot Improves Outcome of Radiofrequency Ablation in Experimental Carcinoma. Radiological Society of North America 2006 Scientific Assembly and Annual Meeting, November 26 - December 1, 2006 ,Chicago IL.
http://archive.rsna.org/2006/4434176.html