To evaluate the efficacy of TREAT in the detection of hemodynamically significant carotid artery stenosis (CAS) by assessment of flow delay.
35 patients (16 female, 19 male, age 69.5 10.2) with suspected CAS underwent high resolution (HR)-MRA of the supraaortic vessels. HR-MRA was performed on a 1.5T MR-system using a fast 3D-GRE sequence with parallel imaging (TR/ TE / Voxel size /iPAT factor - 3.76ms/ 1.24ms/ 0.9x0.7x0.9mm³ / 2) and a bolus of 15ml of gadobutrol. Time-resolved MRA was performed with a 3D-TREAT sequence (TR/ TE / Voxel size /iPAT factor – 2.29ms/ 0.95ms/ 2.0x1.4x2.0mm³/ 2) acquiring 23 3D data sets, one every 2.3s after the injection of a 10ml bolus of gadobutrol. TREAT combines view-sharing techniques to undersample k-space together with parallel imaging techniques to maximize temporal and spatial resolution.
The presence of CAS and the vessel area within and 2cm after the CAS was determined on multiplanar reconstructions. The degree of stenosis (%) was calculated based on HR-MRA data as a reference. CAS >75% were considered hemodynamically significant. For semiquantitative assessment of flow changes, signal-intensity over time curves (SIVTC) were generated from TREAT data. Regions of interest were placed in both common and internal carotid arteries. SIVTCs in the common carotid arteries served as reference for the determination of delayed flow in the stenotic vessel.
All TREAT measurements were diagnostic. No CAS was present in 10 patients, 11 patients had CAS 75%. In patients without CAS, no flow delay was found. Flow delay was identified in 2/11 patients with CAS 75%. Mean flow delay with CAS 75% the mean flow delay was 3.9s.
TREAT is an easily applicable and effective tool to monitor flow delay in stenotic carotid arteries. The identification of flow delay on TREAT imaging is highly indicative of a hemodynamically significant CAS.
Detection of delayed flow is an easy applicable and sensitive marker for hemodynamically significant carotid artery stenoses.